INDESTRUCT "HIGH AMBIENT" (-HA) WATER COOLERS

INDESTRUCT "HIGH AMBIENT" (-HA) WATER COOLERS are "heaviest-duty" and designed for hot climates and are able to cool 115°F (46°C) water down to 50°F (10°C) in ambient temperatures as high as 120°F (49°C). They are built with the most durable materials and components (Epoxy Coated) to withstand even the most excessive demands of heavy industry. This has become the unit-of-choice for many desert countries/regions around the world.

FEATURES

  • Large Storage Type Cooling Tank Buffers and pre-cools 115°F (46°C) inlet water. Prevents overloading of compressor.
  • Oversized Condensing Unit Never overloads in high ambient areas. Large fan keeps unit running cool and efficient in 120°F (49°C) temperatures.
  • Extra Reserve Capacity Permits a single cooler to serve several fixtures and exceed peak demands.
  • Rugged Corrosion Resistant Construction 16 gauge steel cabinet, 304 stainless steel cooling tank and evaporator, copper piping, aluminum condenser and tank housing.

HIGH AMBIENT INDESTRUCT MODELS (English)
MODEL NUMBER

GAL STORAGE

gallons

CAPACITY (120°F AMBIENT 115°F - 50°F)

COMP MOTOR

HP

DIMENSIONS

inches

SHIPPING WEIGHT

lbs.

GPH PERSONS W D H
IM-4-HA 4 8 113 1/4 20.5 15 40 350
IM-7-HA 7 16 200 1/3 29 15 40 400
IM-14-HA 14 22 275 1/2 32 18 40 470
IM-25-HA 25 30 375 3/4 36 24 42 610
IM-40-HA 40 60 750 1-1/2 55 25 42 950

* Water cooled condensers available...Use suffix -W

** Other voltage and fixture options...consult .pdf spec sheet and/or factory.

HIGH AMBIENT INDESTRUCT MODELS (Metric)
MODEL NUMBER

GAL STORAGE

liters

CAPACITY (43°C AMBIENT 32°C - 10°C)

COMP MOTOR

HP

DIMENSIONS

cm

SHIPPING WEIGHT

kg.

LPH PERSONS W D H
IM-4-HA 15 30 113 1/4 52 38 101.6 159
IM-7-HA 26 60 200 1/3 73.7 38 101.6 182
IM-14-HA 53 83 275 1/2 81.2 45.7 101.6 214
IM-25-HA 94 113 375 3/4 91.4 61 106.7 277
IM-40-HA 151 227 750 1-1/2 139.7 63.5 106.7 431

* Water cooled condensers available...Use suffix -W

** Other voltage and fixture options...consult .pdf spec sheet and/or factory.

SPECIFICATIONS

CABINET

18 gauge steel or stainless steel (as specified) on heavy angle frame with removable front panel for complete access to all components. All stainless steel top and corner legs.

COOLING TANK

Heavy stainless steel tank tested at 250 psi for 125 psi working pressure with heavy stainless steel immersion coil type evaporator. Tank storage equal to at least 1/2 of recovery capacity to meet all peak demands for drinking and thermos filling at breaks, shift changes, etc. Insulated tank housed in a rust-proofed steel box.

CONDENSING UNIT

Hermetic, semi-hermetic or open type belt driven compressor (as specified), air or water cooled condenser, freon charged with automatic controls and freeze-up protection. Oversized to handle up to 120°F (49°C) ambient temperatures.

COOLING PACKAGE

Cooling tank in insulated housing, condensing unit and all controls built as self-contained cooling package that can be easily removed for servicing.