Shower Chillers

SHOWERS / SPAS / POOLS / BATHS / COLD PLUNGES / EYE WASH
In climates where both ambient and inlet water temperatures often exceed 115°F [45°C], it is important to have a large reservoir of cool water for shower water use. Filtrine chillers are engineered to handle these high temperatures and provide a stand-by reservoir of cool 59°F [15°C] water.

OPTIONS

  • EXPLOSION PROOF DESIGN: Insures safety where atmosphere is laden with chemical or gas elements that create a potential explosion hazard
  • RECIRCULATING PUMP: Consult factory for sizing/capacity
  • ANODIZED ALUMINIUM CABINET: Weather-resistant for outdoor use
  • FILTER: Please consult factory
  • UV STERILIZER: Please consult factory

INDESTRUCT SHOWER WATER CHILLER MODELS (English)
MODEL NUMBER

GAL STORAGE

gallons

SHOWERS PER HR

@ 50 GAL PER SHOWER

COMP MOTOR

HP

TYPICAL DIMENSIONS

inches

SHIPPING WEIGHT

lbs.

NUMBER OF SHOWERS HOURS BTWN DRAW W D H
SH-50-1/2 50 1 3 1/2 29 29 70 650
SH-75-3/4 75 1 3 3/4 34 27 84 800
SH-130-1 130 2 4 1 84 34 60 1750
SH-130-2 130 2 2 2 84 34 64 1850
SH-260-2 260 4 6 2 94 60 70 3800
SH-260-3 260 4 3 3 96 62 72 4000
SH-520-3 520 8 5 3 112 52 82 5000
SH-520-5 520 8 3 5 112 52 82 5500
SH-880-10 880 15 3 10 116 72 84 7000

* Water cooled condensers available...Use suffix -W

** Other voltage and fixture options...consult .pdf spec sheet and/or factory.

**PLEASE NOTE: Capacities are based on providing 59°F water directly to the fixture(s) (possible mixing valve configurations not considered in calculations).

INDESTRUCT SHOWER WATER CHILLER MODELS (Metric)
MODEL NUMBER

GAL STORAGE

liters

SHOWERS PER HR

@ 50 GAL PER SHOWER

COMP MOTOR

HP

TYPICAL DIMENSIONS

cm

SHIPPING WEIGHT

kg.

NUMBER OF SHOWERS HOURS BTWN DRAW W D H
SH-50-1/2 189.2 1 3 1/2 121.9 68.6 114.3 294.8
SH-75-3/4 283.9 1 3 3/4 137.2 71.1 121.9 362.9
SH-130-1 492.1 2 4 1 213.4 86.4 152.4 793.8
SH-130-2 492.1 2 2 2 213.4 86.4 162.6 839.1
SH-260-2 984.2 4 6 2 238.8 152.4 177.8 1,723.7
SH-260-3 984.2 4 3 3 243.8 157.5 182.9 1,814.4
SH-520-3 1,968.4 8 5 3 284.5 132.1 208.3 2,268
SH-520-5 1,968.4 8 3 5 284.5 132.1 208.3 2,494.8
SH-880-10 3,331.2 15 3 10 294.6 182.9 213.4 3,175.1

* Water cooled condensers available...Use suffix -W

** Other voltage and fixture options...consult .pdf spec sheet and/or factory.

**PLEASE NOTE: Capacities are based on providing 59°F water directly to the fixture(s) (possible mixing valve configurations not considered in calculations).

SPECIFICATIONS

CABINET Heavy gauge painted aluminum panels on welded steel frame with stainless steel top and corner legs. Panels removable without tools for access to all components.

COOLING TANK

Cooling tank #304 stainless steel, insulated with closed cell thermoelastomer with stainless steel immersion coil evaporator. #316 stainless steel also available.

CONDENSING UNIT

Over-sized compressor mounted on vibration isolators. Extra large copper condenser with aluminum fins and heavyduty fan motor, all designed to operate in ambient of 120°F [49°C]. Complete system charge with HFC refrigerant, capacity-tested and ready for operation.

CONTROLS

Chiller provided with complete controls for automatic operation including: adjustable thermostat, high/low pressure control, freeze control, head and suction gauges, thermostatic expansion valve, refrigerant dehydrator, liquid indicator and magnetic starters.

ELECTRICAL

110-120/1/60, 220-240/1/60*, 200-220/3/60**, 440-480/3/60**,

230/1/50*, 380/415/50** or 380/3/60**.

* SH-50-1/2 to SH-130-1 ** SH-50-1/2 to SH-520-5